• The CH(n+1)F, CH(n+1)IE, MS(n+1)A, ELS(n+1)B, and
ELS(n+1)A bits are channel (n+1) bits.
• The Dual Edge Capture mode must be used with
ELS(n)B:ELS(n)A = 0:1 or 1:0, ELS(n+1)B:ELS(n+1)A =
0:1 or 1:0 and the FTM counter in Free running counter.
39.4.24.1 One-Shot Capture mode
The One-Shot Capture mode is selected when (DECAPEN = 1), and (MS(n)A = 0). In
this capture mode, only one pair of edges at the channel (n) input is captured. The
ELS(n)B:ELS(n)A bits select the first edge to be captured, and ELS(n+1)B:ELS(n+1)A
bits select the second edge to be captured.
The edge captures are enabled while DECAP bit is set. For each new measurement in
One-Shot Capture mode, first the CH(n)F and CH(n+1) bits must be cleared, and then the
DECAP bit must be set.
In this mode, the DECAP bit is automatically cleared by FTM when the edge selected by
channel (n+1) is captured. Therefore, while DECAP bit is set, the one-shot capture is in
process. When this bit is cleared, both edges were captured and the captured values are
ready for reading in the C(n)V and C(n+1)V registers.
Similarly, when the CH(n+1)F bit is set, both edges were captured and the captured
values are ready for reading in the C(n)V and C(n+1)V registers.
39.4.24.2
Continuous Capture mode
The Continuous Capture mode is selected when (DECAPEN = 1), and (MS(n)A = 1). In
this capture mode, the edges at the channel (n) input are captured continuously. The
ELS(n)B:ELS(n)A bits select the initial edge to be captured, and ELS(n+1)B:ELS(n+1)A
bits select the final edge to be captured.
The edge captures are enabled while DECAP bit is set. For the initial use, first the
CH(n)F and CH(n+1)F bits must be cleared, and then DECAP bit must be set to start the
continuous measurements.
When the CH(n+1)F bit is set, both edges were captured and the captured values are
ready for reading in the C(n)V and C(n+1)V registers. The latest captured values are
always available in these registers even after the DECAP bit is cleared.
Functional description
K22F Sub-Family Reference Manual, Rev. 4, 08/2016
1008 NXP Semiconductors

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NXP Semiconductors K22F series and is the answer not in the manual?

NXP Semiconductors K22F series Specifications

General IconGeneral
BrandNXP Semiconductors
ModelK22F series
CategoryController
LanguageEnglish

Related product manuals