General-purpose timers (TIM2/TIM3/TIM4) RM0444
650/1390 RM0444 Rev 5
Downcounting configuration
Downcounting is active when DIR bit in TIMx_CR1 register is high. Refer to Downcounting
mode on page 632.
In PWM mode 1, the reference signal ocxref is low as long as TIMx_CNT>TIMx_CCRx else
it becomes high. If the compare value in TIMx_CCRx is greater than the auto-reload value in
TIMx_ARR, then ocxref is held at 100%. PWM is not possible in this mode.
PWM center-aligned mode
Center-aligned mode is active when the CMS bits in TIMx_CR1 register are different from
‘00 (all the remaining configurations having the same effect on the ocxref/OCx signals). The
compare flag is set when the counter counts up, when it counts down or both when it counts
up and down depending on the CMS bits configuration. The direction bit (DIR) in the
TIMx_CR1 register is updated by hardware and must not be changed by software. Refer to
Center-aligned mode (up/down counting) on page 635.
Figure 192 shows some center-aligned PWM waveforms in an example where:
TIMx_ARR=8,
PWM mode is the PWM mode 1,
The flag is set when the counter counts down corresponding to the center-aligned
mode 1 selected for CMS=01 in TIMx_CR1 register.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32G0 1 Series and is the answer not in the manual?

ST STM32G0 1 Series Specifications

General IconGeneral
BrandST
ModelSTM32G0 1 Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals