EasyManuals Logo

NETGEAR M4100 Series ProSAFE User Manual

NETGEAR M4100 Series ProSAFE
578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #231 background imageLoading...
Page #231 background image
Routing Commands
231
M4100 Series ProSAFE Managed Switches
no arp retries
This command configures the default ARP count of maximum request for retries.
arp timeout
This command configures the ARP entry ageout time.
The value for <seconds> is a valid positive integer, which represents the IP ARP entry
ageout time in seconds. The range for <seconds> is between 15-21600 seconds.
no arp timeout
This command configures the default ARP entry ageout time.
clear arp-cache
This command causes all ARP entries of type dynamic to be removed from the ARP cache. If
the gateway keyword is specified, the dynamic entries of type gateway are purged as well.
clear arp-switch
Use this command to clear the contents of the switch’s Address Resolution Protocol (ARP)
table that contains entries learned through the Management port. To observe whether this
command is successful, ping from the remote system to the DUT. Issue the show arp
switch command to see the ARP entries. Then issue the clear arp-switch command
and check the show arp switch entries. There will be no more arp entries.
Format no arp retries
Mode Global Config
Default 1200
Format arp timeout <seconds>
Mode Global Config
Format no arp timeout
Mode Global Config
Format clear arp-cache [gateway]
Mode Privileged EXEC
Format clear arp-switch
Mode Privileged EXEC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals