Management Commands
492
M4100 Series ProSAFE Managed Switches
no snmp-server community
Use this command to remove this community name from the table. The <name> is the
community name to be deleted.
snmp-server community ipaddr
Use this command to set a client IP address for an SNMP community. The address is the
associated community SNMP packet sending address and is used along with the client IP
mask value to denote a range of IP addresses from which SNMP clients might use that
community to access the device. A value of 0.0.0.0 allows access from any IP address.
Otherwise, this value is ANDed with the mask to determine the range of allowed client IP
addresses. The name is the applicable community name.
no snmp-server community ipaddr
Use this command to set a client IP address for an SNMP community to 0.0.0.0. The name is
the applicable community name.
snmp-server community ipmask
Use this command to set a client IP mask for an SNMP community. The address is the
associated community SNMP packet sending address and is used along with the client IP
address value to denote a range of IP addresses from which SNMP clients might use that
community to access the device. A value of 255.255.255.255 allows access from only one
station and uses that machine’s IP address for the client IP address. A value of 0.0.0.0 allows
access from any IP address. The name is the applicable community name.
Format no snmp-server community <name>
Mode Global Config
Default 0.0.0.0
Format snmp-server community ipaddr <ipaddr> <name>
Mode Global Config
Format no snmp-server community ipaddr <name>
Mode Global Config
Default 0.0.0.0
Format snmp-server community ipmask <ipmask> <name>
Mode Global Config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals