• Active. Device is plugged in and the device is recognized if device is not mounted.
• Inactive. Device is not mounted.
• Invalid. Device is not present or invalid device is plugged in.
Utility Commands
441
M4100 Series ProSAFE Managed Switches
Command example:
The following is the output if the device is plugged into the USB slot.
(NETGEAR Switch) #show USB device
Device Status………………………………………………… Active
Manufacturer…………………………………………………… xxxx
Serial Number………………………………………………… yyyyy
USB Version Compliance………………………… 2.0
Class Code………………………………………………………… abc
Subclass Code………………………………………………… acb
Protocol……………………………………………………………… 0x0
Vendor ID…………………………………………………………… zzzzz
Product ID………………………………………………………… aaaaa
dir usb
This command displays USB device contents and memory statistics.
Parameter Description
Device Status This field specifies the current status of device. Following are possible device status
states:
Manufacturer Manufacturer details.
Serial Number Serial number of the device.
USB Version
Compliance
Version of the USB device.
Class Code Device Class
Subclass Code Device SubClass
Protocol Device Protocol
Vendor ID Vendor specifies details of device-Vendor ID
Product ID Vendor specifies details of device-Product ID
Format dir usb
Mode Privileged EXEC