Utility Commands
379
M4100 Series ProSAFE Managed Switches
week—Week of the month. (Range: 1-5, first, last)
day—Day of the week. (Range: The first three letters by name; sun, for example.)
month—Month. (Range: The first three letters by name; jan, for example.)
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh:0-23, mm: 0-59)
offset—Number of minutes to add during the summertime. (Range:1-1440)
acronym—The acronym for the time zone to be displayed when summertime is in effect.
(Range: Up to four characters)
Command example:
(NETGEAR Switch)(Config)# clock summer-time recurring 1 sun jan
00:10 2 mon mar 10:00 offset 1 zone ABC
clock summer-time date
Use this command to set the summertime offset to UTC. If the optional parameters are not
specified, they are read as either 0 or \0, as appropriate.
date—Day of the month. (Range: 1-31)
month—Month. (Range: The first three letters by name; jan, for example.)
year—Year. (Range: 2000-2097)
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh: 0-23, mm: 0-59)
offset—Number of minutes to add during the summertime. (Range:1-1440)
acronym—The acronym for the time zone to be displayed when summertime is in effect.
(Range: Up to four characters)
Command example:
(NETGEAR Switch)(config)# clock summer-time date 1 Apr 2007 02:00 28 Oct 2007 offset 90
zone EST
Format clock summer-time recurring {USA | EU | {<week> <day> <month>
<hh:mm> <week> <day> <month> <hh:mm>}} [offset <offset>] [zone
<acronym>]
Mode Global Config
Format clock summer-time date {<day> <month> <year> <hh:mm> <day> <month>
<year> <hh:mm>} [offset <offset>] [zone <acronym>]
Mode Global Config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals