Utility Commands
362
M4100 Series ProSAFE Managed Switches
show logging email config
This command displays information about the email alert configuration.
show logging email statistics
This command displays email alerting statistics.
Format show logging email config
Mode Privileged EXEC
Term Definition
Email Alert Logging The administrative status of the feature: enabled or disabled
Email Alert From Address The email address of the sender (the switch).
Email Alert Urgent
Severity Level
The lowest severity level that is considered urgent. Messages of this type are
sent immediately.
Email Alert Non Urgent
Severity Level
The lowest severity level that is considered non-urgent. Messages of this type,
up to the urgent level, are collected and sent in a batch email. Log messages
that are less severe are not sent in an email message at all.
Email Alert Trap Severity
Level
The lowest severity level at which traps are logged.
Email Alert Notification
Period
The amount of time to wait between non-urgent messages.
Email Alert To Address
Table
The configured email recipients.
Email Alert Subject Table The subject lines included in urgent (Type 1) and non-urgent (Type 2)
messages.
For Msg Type urgent,
subject is
The configured email subject for sending urgent messages.
For Msg Type non-urgent,
subject is
The configured email subject for sending non-urgent messages.
Format show logging email statistics
Mode Privileged EXEC
Term Definition
Email Alert Operation
Status
The operational status of the email alerting feature.
No of Email Failures The number of email messages that have attempted to be sent but were
unsuccessful.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals