Switching Commands
61
M4100 Series ProSAFE Managed Switches
The native VLAN must be in the allowed VLAN list for tagging of received untagged packets.
Otherwise, untagged packets are discarded. Packets marked with the native VLAN are
transmitted untagged from the trunk port. The default ID is 1, the default VLAN.
no switchport trunk native vlan
Use this command to reset the trunk mode native VLAN of the switch port to its default value.
switchport access vlan
Use this command to configure the VLAN on the access port. You can assign one VLAN only
to the access port. The access port is member of VLAN 1 by default. You can assign the
access port to a VLAN other than VLAN 1. If you remove the access VLAN on the switch, the
access port becomes a member of VLAN 1. If you configure the access port as a member of
a VLAN that does not exist, an error occurs and the configuration does not change.
no switchport access vlan
This command resets the switch port access mode VLAN to its default value.
show interfaces switchport
Use this command to either display the switch port status for all interfaces, for a specific
interface, or for a specific mode (access, trunk, or general). If you select a mode but do not
specify the interface for the mode, the selected mode is displayed for all interfaces.
Default 1 (default VLAN)
Format switchport trunk native vlan <vlan-id>
Mode Interface Config
Format no switchport trunk native vlan
Mode Interface Config
Default 1 (default VLAN)
Format switchport access vlan <vlan-id>
Mode Interface Config
Format no switchport access vlan
Mode Interface Config
Format show interfaces switchport {[<slot/port>] | {access | trunk |
general} [<slot/port>]}
Mode Privileged EXEC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)