Utility Commands
359
M4100 Series ProSAFE Managed Switches
no logging email
This command disables email alerting.
logging email urgent
This command sets the lowest severity level at which log messages are emailed immediately
in a single email message. You can specify the <severitylevel> value as either an
integer from 0 to 7 or symbolically through one of the following keywords: emergency (0),
alert (1), critical (2), error (3), warning (4), notice (5), info (6), or debug (7).
Specify none to indicate that log messages are collected and sent in a batch email at a
specified interval.
no logging email urgent
This command resets the urgent severity level to the default value.
logging email message-type to-addr
This command configures the email address to which messages are sent. The message
types supported are urgent, non-urgent, or both. For each supported severity level,
multiple email addresses can be configured. The <to-email-addr> variable is a standard
email address, for example admin@yourcompany.com.
Default Disabled; when enabled, log messages at or above severity warning (4) are emailed
Format logging email [<severitylevel>]
Mode Global Config
Format no logging email
Mode Global Config
Default Alert (1) and emergency (0) messages are sent immediately
Format logging email urgent {<severitylevel> | none}
Mode Global Config
Format
no logging email urgent
Mode Global Config
Format logging email message-type {urgent |non-urgent |both} to-addr
<to-email-addr>
Mode Global Config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals