Management Commands
493
M4100 Series ProSAFE Managed Switches
no snmp-server community ipmask
Use this command to set a client IP mask for an SNMP community to 0.0.0.0. The name is
the applicable community name.
The community name might be up to 16 alphanumeric
characters.
snmp-server community mode
Use this command to activate an SNMP community. If a community is enabled, an SNMP
manager associated with this community manages the switch according to its access right. If
the community is disabled, no SNMP requests using this community are accepted. In this
case the SNMP manager associated with this community cannot manage the switch until the
Status is changed back to Enable.
private and public communities - enabled
other four - disabled
no snmp-server community mode
Use this command to deactivate an SNMP community. If the community is disabled, no
SNMP requests using this community are accepted. In this case the SNMP manager
associated with this community cannot manage the switch until the Status is changed back to
Enable.
snmp-server community ro
Use this command to restrict access to switch information. The access mode is read-only
(also called public).
Format no snmp-server community ipmask <name>
Mode Global Config
Default
Format snmp-server community mode <name>
Mode
Global Config
Format no snmp-server community mode <name>
Mode Global Config
Format snmp-server community ro <name>
Mode Global Config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals