Power over Ethernet Commands
324
M4100 Series ProSAFE Managed Switches
no poe traps
Use this command to disable logging the PoE traps.
show poe
Use this command to get global information regarding the PoE status.
Privileged EXEC
User EXEC
ON—Indicates that the PoE controller is actively delivering power
.
OFF—Indicates that the PoE controller is not delivering power
.
F
AULTY—Indicates that the PoE controller is not functioning.
Format no poe traps
Mode
Global Config
Format show poe
Mode
Term Definition
Firmware Version The firmware version of the PoE controller on the switch.
PSE Main
Operational Status
Indicates the status of the PoE controller:
Total Power (Main
AC)
Indicates the maximum amount of power that can be delivered by this PoE unit when
on system power.
Total Power (RPS) Indicates the maximum amount of power that can be delivered by this PoE unit when
on RPS.
Total Power (PD) Indicates the maximum amount of power that can be delivered by this PoE unit when
on the PD source. This field is applicable only for the GSM5212P.
Power Source Indicates the power source being used: main AC, RPS, or PD. If PD is used as a
source, “PD <portNo>” is displayed.
Threshold Power System can power up one port, if consumed power is less than this power. That is,
the consumed power can be between the total power and threshold power values.
The threshold power value is effected by changing the system usage threshold.
Total Power
Consumed
Indicates the total amount of power being delivered to all the devices plugged into the
switch.
Usage Threshold Indicates the usage threshold level.
Power
Management Mode
Indicates the management mode used by the PoE controller.
Auto Reset Mode Indicates whether the PoE ports will be automatically reset in case of an error on a
port.
Traps Configures the traps.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals