Switching Commands
52
M4100 Series ProSAFE Managed Switches
vlan protocol group
This command adds protocol-based VLAN groups to the system. When it is created, the
protocol group will be assigned a unique number (1-128) that will be used to identify the
group in subsequent commands.
no vlan protocol group
This command removes a protocol group.
vlan protocol group name
This command assigns a name to a protocol-based VLAN group. The groupname variable
can be a character string of 0–16 characters.
no vlan protocol group name
This command removes the name from a protocol-based VLAN group.
vlan protocol group add protocol
This command adds the protocol to the protocol-based VLAN identified by groupid. A group
may have more than one protocol associated with it. Each interface and protocol combination
can only be associated with one group. If adding a protocol to a group causes any conflicts
with interfaces currently associated with the group, this command fails and the protocol is not
added to the group. The possible values for protocol-list includes the keywords ip, arp, and
ipx and hexadecimal or decimal values ranging from 0x0600 (1536) to 0xFFFF (65535). The
protocol list can accept up to 16 protocols separated by a comma.
Format vlan protocol group <1-128>
Mode Global Config
Format no vlan protocol group <1-128>
Mode Global Config
Format vlan protocol group name <1-128> <groupname>
Mode Global Config
Format no vlan protocol group name <1-128>
Mode Global Config
Default none
Format vlan protocol group add protocol <groupid> <ethertype>
{<protocol-list> | arp | ip | ipx}
Mode Global Config

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)

Related product manuals