Utility Commands
402
M4100 Series ProSAFE Managed Switches
capture file size
Use this command to configure file capture options. The command is persistent across a
reboot cycle. The range is from 2 to 512 Kbytes.
no capture file size
Use this command to reset the file size to the default (512 Kbytes).
capture line wrap
This command enables wrapping of captured packets in line mode when the captured
packets reaches full capacity.
no capture line wrap
This command disables wrapping of captured packets and configures capture packet to stop
when the captured packet capacity is full.
show capture packets
Use this command to display packets captured and saved to RAM. It is possible to capture
and save into RAM, packets that are received or transmitted through the CPU. A maximum
128 packets can be saved into RAM per capturing session. A maximum 128 bytes per packet
can be saved into the RAM. If a packet holds more than 128 bytes, only the first 128 bytes
are saved; data more than 128 bytes is skipped and cannot be displayed in the CLI.
Capturing packets is stopped automatically when 128 packets are captured and have not yet
been displayed during a capture session. Captured packets are not retained after a reload
cycle.
Default 512 Kbytes
Format capture file size <file-size>
Mode Global Config
Format no capture file size
Mode Global Config
Default Disabled
Format capture line wrap
Mode Global Config
Format no capture line wrap
Mode Global Config