Log Messages
555
M4100 Series ProSAFE Managed Switches
OS USL: A Trunk being created by bcmx
already existed in USL
Possible synchronization issue between
the application, hardware, and sync layer
OS USL: A Trunk being destroyed doesn't exist
in USL
Possible synchronization issue between
the application, hardware, and sync layer.
OS USL: A Trunk being set doesn't exist in
USL
Possible synchronization issue between
the application, hardware, and sync layer.
OS USL: failed to sync trunk table on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
OS USL: Mcast entry not found on a join Possible synchronization issue between
the application, hardware, and sync layer
OS USL: Mcast entry not found on a leave Possible synchronization issue between
the application, hardware, and sync layer
OS USL: failed to sync dvlan data on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
OS USL: failed to sync policy table on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
OS USL: failed to sync VLAN table on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
OS Invalid LAG id x Possible synchronization issue between
the BCM driver and HAPI
OS Invalid uport calculated from the BCM uport
bcmx_l2_addr->lport = x
Uport not valid from BCM driver.
OS Invalid USP calculated from the BCM
uport\nbcmx_l2_addr->lport = x
USP not able to be calculated from the
learn event for BCM driver.
OS Unable to insert route R/P Route ‘R’ with prefix ‘P’ could not be
inserted in the hardware route table. A retry
will be issued.
OS Unable to Insert host H Host ‘H’ could not be inserted in hardware
host table. A retry will be issued.
OS USL: failed to sync L3 Intf table on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
OS USL: failed to sync L3 Host table on unit=x Could not synchronize unit x due to a
transport failure or API issue on remote
unit. A synchronization retry will be issued
Table 54. System General Error Messages
Component Message Cause

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series ProSAFE and is the answer not in the manual?

NETGEAR M4100 Series ProSAFE Specifications

General IconGeneral
Product TypeManaged Switch
Form FactorRack-mountable
LayerLayer 2/Layer 3
ManagementWeb-based, CLI, SNMP
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1x
DimensionsVaries by model
WeightVaries by model
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-20° to 70° C (-4° to 158° F)
PoE SupportYes (on select models)