2-148 Service Manual
5058-030
3
Check the sensor (stacker bin
level encoder) for proper
connection.
Is the above component
properly connected?
Replace the sensor (stacker bin
level encoder). Go to “Sensor
(stacker bin level encoder)
removal” on page 4-330.
Replace the connection.
4
Check the sensor (stacker bin
level R) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (stacker bin
level 1).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 6. Go to step 5.
5
Check the sensor (stacker bin
level R) for proper connection.
Is the above component
properly connected?
Replace the sensor (stacker bin
level R). Go to
“Sensor (stacker
bin level R) removal” on
page 4-331.
Replace the connection.
6
Check the sensor (stacker bin
level F) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (stacker bin
level 2).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 8. Go to step 7.
7
Check the sensor (stacker bin
level F) for proper connection.
Is the above component
properly connected?
Replace the sensor (stacker bin
level F). Go to
“Sensor (stacker
bin level F) removal” on
page 4-331.
Replace the connection.
Step Action and questions Yes No