4. Remove the screw securing the sensor (booklet front tamper HP) bracket from the booklet unit assembly.
5. Remove sensor (booklet front tamper HP) (A).
Sensor (booklet knife folding) removal
1. Remove the booklet unit assembly. See “Booklet unit chassis removal” on page 4-263.
1. Remove the Complete booklet unit assembly left cover. See “Booklet unit assembly left cover removal
on page 4-262.
2. Rotate knife sector gear clockwise until the flag is in the folding sensor position.
3. Remove one screw securing the sensor (knife HP sensor & knife folding sensor) from the knife frame
assembly.
4. Disconnect the connector from the sensor (booklet knife folding) (A).
A
Left
Connector