2-196 Service Manual
5058-030
486.05 Sensor (lower media exit) lag jam
6
Check the exit motor for proper
operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Exit motor.
Does the above component
operate properly?
Go to step 8. Go to step 7.
7
Check the exit stepper motor for
proper connection.
Is the above component
properly connected?
Replace the stepper motor.
Go to “Stepper motor (exit)
assembly and belt (exit)
removal” on page 4-348.
Replace the connection.
8
Check the finisher PCBA for
proper connection.
Is the above component
properly connected?
Go to Step 9. Replace the connections.
9
POR the machine.
Does the error continue?
Replace the finisher PCBA.
Go to “Finisher PCBA removal”
on page 4-281.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
2
Check the sensor (lower media
exit) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
3. Touch Sensor (lower media
exit).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to Step 4. Go to Step 3.
Step Action and questions Yes No