4-276 Service Manual
5058-030
7. Remove the finisher diverter gate solenoid (A).
Note: The link (C) may remain inserted into the finisher.
8. Remove the link.
Note: When the link is removed, the finisher diverter gate may become detached. See “Finisher diverter
gate removal” on page 4-275.
Finisher front door assembly removal
1. Open the finisher front door assembly (A).
2. Remove the three screws securing the finisher front door assembly.