4-376 Service Manual
5058-030
Go Back
Previous
Next
3. Push the two ends of the HCF separation roll assembly (A) inward, and move it upward in the direction of
the arrow to release it from the HCF media feed unit assembly (B).
4. Remove the HCF separation roll assembly (A).
Note: When removing the HCF separation roll assembly (A), do not touch the rubber surface.
Note: Before re-installing the HCF separation roll assembly (A), do not touch the rubber surface.
HCF separation roll shaft assembly removal
1. Remove the HCF media tray assembly. See “HCF media tray assembly removal” on page 4-366.
2. Remove the HCF media feed unit assembly. See “HCF feed unit removal” on page 4-362.
3. Remove the HCF feed lift motor. See “HCF feed lift motor removal” on page 4-360.
4. Remove the HCF feed lift gear bracket. See HCF feed lift gear bracket removal” on page 4-360.
5. Remove the HCF separation roll assembly. See “HCF separation roll assembly removal” on
page 4-375.
Front
B
A