Repair information 4-169
5058-030
3. Rotate the transfer belt lever counterclockwise to the unlock position.
4. Open the printhead retract door.
Warning: After the photoconductor units are removed, ensure that they are properly covered so that they are
not exposed to light.
5. Remove the four photoconductor units.
6. Remove the transfer belt lever. See “Transfer belt lever removal” on page 4-174.
7. Open the printer left duplex door assembly.
8. Remove the fuser. See “Fuser assembly removal” on page 4-78.
9. Remove the e-clip (A) securing the rear plastic support strap to the printer left duplex door assembly.