2-14 Service Manual
5058-030
115.07
Service printhead
error
Multiple LED printhead read failure Communication failed between the upper
engine PCBA and more than one LED
printhead.
Go to “115.07 Multiple LED printhead
read failure” on page 2-40.
115.08
Service printhead
error
Single LED printhead read failure Communication failed between the upper
engine PCBA and one LED printhead.
Go to “115.08 Single LED printhead read
failure” on page 2-40.
115.09
Service printhead
error
Multiple LED printhead write failure Communication failed between the upper
engine PCBA and more than one LED
printhead.
Go to “115.09 Multiple LED printhead
write failure” on page 2-41.
115.10
Service printhead
error
Single LED printhead write failure Communication failed between the upper
engine PCBA and one LED printhead.
Go to “115.10 Single LED printhead
write failure” on page 2-41.
115.11
Service printhead
error
Multiple LED printhead communication
failure
Communication failed between the upper
engine PCBA and more than one LED
printhead.
Go to “115.11 Multiple LED printhead
communication failure” on page 2-42.
115.12
Service printhead
error
Single LED printhead communication
failure
Communication failed between the upper
engine PCBA and one LED printhead.
Go to “115.12 Single LED printhead
communication failure” on page 2-43.
115.13
Service printhead
error
Multiple LED printhead clock failure Synchronization failed on multiple LED
printheads.
Go to “115.13 Multiple LED printhead
clock failure” on page 2-43.
115.14
Service printhead
error
Single LED printhead clock failure Synchronization failed on one LED
printhead.
Go to “115.14 Single LED printhead
clock failure” on page 2-44.
115.15
Service tray error
Tray module logic failure An error was detected in the tray module.
Go to “115.15 Tray module logic failure”
on page 2-44.
120.01
Service fuser error
Fuser motor failure An error was detected in the fuser motor.
Go to “120.01 Fuser motor failure” on
page 2-45.
120.02
Service fuser error
Fuser pressure roll retract motor failure An error was detected at the fuser
pressure rolls and motor.
Go to “120.02 Fuser pressure roll retract
motor failure” on page 2-46.
1xx service error codes
Error code Description Action