Page #276 background imageLoading...
Page #276 background image
TDS5000B Online Programmer Guide
-- 2 5 6 --
DISplay:STYle
Description
This command sets or queries how the data is displayed for normal and
FastAcq modes. This command is equivalent to selecting Display Style
from the Display menu and choosing a style.
Group
Display Control
Syntax 1
DISplay:STYle {VECtors|DOTs|INTENSIFied}
Syntax 2
DISplay:STYle?
Arguments
H VECtors
This connects adjacent data points. New points immediately replace
old ones.
H DOTs
This displays individual data points. New points immediately replace
old ones.
H INTENSIFied
This causes the display to show interpolated samples with dark spaces
(Only the ”real” samples are displayed).
When FastAcq mode is enabled, intensified samples display as dots.
However, turning off FastAcq mode causes the display style to snap
back to its previous setting.
Example 1
DISplay:STYle VECtors
This command sets the display to connect adjacent data points.
Example 2
DISplay:STYle?
This query might return:
:DISPLAY:STYLE INTENSIFIED
This indicates that interpolated samples are not displayed.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals