EasyManuals Logo
Home>Tektronix>Test Equipment>TDS5000B Series

Tektronix TDS5000B Series Online Programmer Guide

Tektronix TDS5000B Series
917 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
TDS5000B Online Programmer Guide
-- 1 5 4 --
CURSor:VBArs:POSITION<x>
Description
This command sets or queries the horizontal position for vertical bar
cursors. The cursor is specified by x, which can be 1 or 2. Values are
with respect to trigger position or the zero reference point for the desig-
nated waveform (if horizontal units are not set to time). Use the CUR-
Sor:VBArs:UNIts command to specify units. The position can appear
in units of base or 1/base.
This command is the equivalent of selecting Cursor Setup from the
Cursors menu, selecting V Bars Cursor Type, and then viewing or edit-
ing the desired cursor position.
Group
Cursor
Related Commands
CURSor:VBArs:UNIts
Syntax 1
CURSor:VBArs:POSITION<x> {<NR3>}
Syntax 2
CURSor:VBArs:POSITION<x>?
Argument
H <NR3>
Specifies the cursor position.
Returns
A floating point value with an exponent.
Example 1
CURSor:VBArs:POSITION2 9.00E-6
Positions the cursor2 vertical bar cursor at 9 ms.
Example 2
CURSor:VBArs:POSITION1?
This command might return
:CURSOR:VBARS:POSITION1 1.0000E-06
indicating that the cursor1 vertical bar is positioned at 1 ms.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals