-- 4 7 4 --
MASK:TESt:SAVEWFM
Description
This command sets or returns the save waveform to file on failure set-
ting. When enabled, this command copies waveform data from active
channels to files when the pass/fail test status changes to ‘Failing’.
Note: This oscilloscope saves files only on the first violation that
causes the pass/fail test to fail. To generate a waveform file for every
violation occurrence, set MASK:TESt:REPeat to ON and
MASK:TESt:WAVEform to 1. Use this technique only when the ex-
pected number of violations is small and the violation occurs intermit-
tently.
Group
Mask
Syntax 1
MASK:TESt:SAVEWFM {OFF|ON|<NR1>}
Syntax 2
MASK:TESt:SAVEWFM?
Arguments
H ON
Turns on copying all active channel waveforms to files.
H OFF
Turns off copying all active channel waveforms to files.
H <NR1>
A 0 turns off copying all active channel waveforms to files, and any
other integer turns on copying all active channel waveforms to files.
Example
MASK:TEST:SAVEWFM ON
Sets the oscilloscope to save the failing waveform data to files.