TDS5000B Online Programmer Guide
-- 3 4 0 --
HORizontal:FASTframe:REF:SOUrce
Description
This command sets or queries FastFrame Reference waveform source.
This is equivalent to selecting FastFrame Setup from the Horiz/Acq
menu and choosing the reference source.
Group
Horizontal
Related Commands
HORizontal:FASTframe:REF:FRAMe, HORizontal:FASTframe:TIME-
stamp:DELTa:<wfm>?, HORizontal:FASTframe:TIMEstamp:REF?,
HORizontal:FASTframe:TRACk
Syntax 1
HORizontal:FASTframe:REF:SOUrce <wfm>
Syntax 2
HORizontal:FASTframe:REF:SOUrce?
Argument
H <wfm>
This specifies the FastFrame Reference waveform source. Valid wa-
veforms include CH<x>, MATH<x>, and REF<x>. The x variable
can be expressed as an integer ranging from 1 through 4 for 4--chan-
nel models and 1 to 2 for 2--channel models.
Example 1
HORizontal:FASTframe:REF:SOUrce CH2
This command sets the horizontal FastFrame waveform reference
source to CH2.
Example 2
HORizontal:FASTframe:REF:SOUrce?
This query might return
:HORIZONTAL:FASTFRAME:REF:SOURCE CH2
This indicates that the FastFrame waveform source is currently set to
CH2.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals