MEASUrement:STATIstics:MODe
Description
This command controls the operation and display of management statis-
tics. This command is equivalent to selecting Measurement Setup from
the Measure menu, clicking the Statistics button and then choosing the
desired Measurement Format.
Group
Measurement
Related Commands
MEASUrement:STATIstics:WEIghting
Syntax 1
MEASUrement:STATIstics:MODe {OFF|ALL|VALUE-
Mean}
Syntax 2
MEASUrement:STATIstics:MODe?
Arguments
H OFF
This turns all measurements off. This is the default value.
H ALL
This turns on statistics and displays all statistics for each measure-
ment.
H VALUEMean
This turns on statistics and displays the value and the mean (µ)of
each measurement.
Example 1
MEASUrement:STATIstics:MODe OFF
This command turns statistic measurements off.
Example 2
MEASUrement:STATIstics:MODe?
This query might return
:MEASUREMENT:STATISTICS:MODE ALL
indicating that measurement statistics are turned on and all statistics are
being displayed for each measurement.