TDS5000B Online Programmer Guide
-- 3 4 5 --
HORizontal:FASTframe:TIMEStamp:BETWeen:<wfm>?
Description
This query--only command returns the relative trigger for the delta time
between the specified frames, within the specified waveform. Valid
waveforms include CH<x>, MATH<x> and REF<x>. The x variable
can be expressed as an integer ranging from 1 through 4 for 4--channel
models and 1 to 2 for 2 --channel models.
The format of the delta time output is as follows:
H HH:MM:SS is hours, minutes, and seconds
H .xxx xxx xxx xxx is fractions of a second to picoseconds
Group
Horizontal
Syntax
HORizontal:FASTframe:TIMEStamp:BETWeen:<wfm>?
<NR1>, <NR1>
Arguments
H <NR1>
This specifies the selected ”from” frame number within the specified
waveform.
H <NR1>
This specifies the selected ”to” frame number within the specified
waveform.
Example
HORIZONTAL:FASTFRAME:TIMESTAMP:BETWEEN:CH1?
5,2
This query might return
:HORIZONTAL:FASTFRAME:TIMESTAMP:BETWEEN:CH1
5,2,”00:00:00.010 000 540 624”
This is the delta of channel 1’s Time Stamp frame 5 -- Time Stamp
frame 2 (TS[5]--TS[2]).

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals