-- 3 3 3 --
HORizontal:FASTframe:COUNt
Description
This command sets or queries FastFrame frame count. This command is
equivalent to selecting Fast Frame Setup from the Horiz/Acq menu and
entering a value in the Frame Count box. FastFrame captures a series of
triggered acquisitions with minimal intervening time.
Group
Horizontal
Related Commands
HORizontal:RECOrdlength
Syntax 1
HORizontal:FASTframe:COUNt <NR1>
Syntax 2
HORizontal:FASTframe:COUNt?
Arguments
H <NR1>
This indicates the number of frames to acquire.
Example 1
HORIZONTAL:FASTFRAME:COUNT 2
This command sets up FastFrame mode to acquire two frames (seg-
ments) of data.
Example 2
HORIZONTAL:FASTFRAME:COUNT?
This query might return
:HORIZONTAL:FASTFRAME:COUNT 4
indicating that FastFrame mode is currently set to acquire 4 frames of
data.