-- 7 5 4 --
TRIGger:A:PULse:WINdow:TYPe
Description
This command sets or queries the window trigger type. This command
is equivalent to selecting Window Setup from the Trig menu and select-
ing Outside Limits or Inside Limits in the Trigger When section.
Group
Trigger
Syntax 1
TRIGger:A:PULse:WINdow:TYPe {INSide|OUTside}
Syntax 2
TRIGger:A:PULse:WINdow:TYPe?
Arguments
H INSide
This argument causes a trigger event to occur when a pulse enters the
window defined by the upper and lower thresholds.
H OUTside
This argument causes a trigger event to occur when a pulse goes out-
side the window defined by the upper and lower thresholds.
Example 1
TRIGger:A:PULse:WINdow:TYPe?
This query might return
:TRIGGER:A:PULSE:WINDOW:TYPE INSIDE
indicating that the window type is set to inside, which will cause a trig-
ger event when a pulse enters the window defined by the upper and
lower thresholds.
Example 2
TRIGger:A:PULse:WINdow:TYPe OUTside
This command sets the window type to outside.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Tektronix TDS5000B Series Specifications

General IconGeneral
Channels2 or 4
Vertical Resolution8 bits
Display TypeColor LCD
Vertical Sensitivity1 mV/div to 10 V/div
Input CouplingAC, DC, GND
Timebase Accuracy± 50 ppm
Operating Temperature0 °C to +50 °C
Bandwidthup to 1 GHz
Sample Rateup to 5 GS/s
Display Size10.4 inches
Input Impedance1 MΩ ± 1%
Trigger TypesEdge, Pulse Width, Logic, Runt, Timeout, Setup/Hold