-- 4 8 6 --
MASK:USER:HTRIGPOS
Description
This command sets or returns the nominal trigger position.(pulse lead-
ing edge) used to draw the mask as a fraction of the display width. The
query form of this command returns the nominal trigger position of the
displayed mask. The set form of this command only affects the User
mask, regardless of the current (displayed) mask.
Group
Mask
Related Commands
MASK:USER:HSCAle?
Syntax 1
MASK:USER:HTRIGPOS <NR3>
Syntax 2
MASK:USER:HTRIGPOS?
Argument
H <NR3>
Is a floating point number in the range of 0.0 to 1.0 that sets the trig-
ger points as a fraction of the display width, referenced from the left
edge of the graticule.
0.0 represents the left edge.
Example
MASK:USER:HTRIGPOS 0.6