-- 3 4 9 --
HORizontal:FASTframe:TIMEStamp:
SELECTED:<wfm>?
Description
This query--only command returns the absolute trigger date and time for
the FastFrame Selected, within the specified waveform. Valid wave-
forms include CH<x>, MATH<x> and REF<x>. The x variable can be
expressed as an integer ranging from 1 through 4 for 4--channel models
and 1 to 2 for 2--channel models.
The format of the output is as follows:
DD MON YYYY HH:MM:SS.xxx xxx xxx xxx
H DD MON YYYY is day, month, and year
H HH:MM:SS is hours, minutes, and seconds
H .xxx xxx xxx xxx is fractions of a second to picoseconds
Group
Horizontal
Related Commands
HORizontal:FASTframe:SELECTED:<wfm>?
Syntax
HORizontal:FASTframe:TIMEStamp:SELECTED:<wfm>?
Example
HORIZONTAL:FASTFRAME:TIMESTAMP:SELECTED:REF1?
This query might return
:HORIZONTAL:FASTFRAME:TIMESTAMP:SELECTED:REF1
”02 MAR 2000 20:10:54:539 037 145 340”
This is the time stamp of FastFrame Selected on reference 1.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals