TDS5000B Online Programmer Guide
-- 5 8 9 --
MEASUrement:MEAS<x>:TYPe
Description
This command sets or queries the measurement type defined for the
specified measurement slot. The measurement slot is specified by x,
which ranges from 1 through 8. This command is equivalent to select-
ing Measurement Setup from the Measure menu and then choosing the
desired measurement type.
Group
Measurement
Syntax 1
MEASUrement:MEAS<x>:TYPe {AMPlitude|AREa|
BURst|CARea|CMEan|CRMs|DELay|DISTDUty|
EXTINCTDB|EXTINCTPCT|EXTINCTRATIO|EYEHeight|
EYEWidth|FALL|FREQuency|HIGH|HITs|LOW|
MAXimum|MEAN|MEDian|MINImum|NCROss|NDUty|
NOVershoot|NWIdth|PBASe|PCROss|PCTCROss|PDUty|
PEAKHits|PERIod|PHAse|PK2Pk|PKPKJitter|
PKPKNoise|POVershoot|PTOT|PWIdth|QFACtor|
RISe|RMS|RMSJitter|PMSNoise|SIGMA1|SIGMA2|
SIGMA3|SIXSigmajit|SNRatio|STDdev|UNDEFINED|
WAVEFORMS}
Syntax 2
MEASUrement:MEAS<x>:TYPe?
Arguments
H AMPlitude
This measures the amplitude of the selected waveform. In other
words, it measures the high value less the low value measured over
the entire waveform or gated region.
Amplitude = High -- Low
H AREa
This measures the voltage over time. The area is over the entire wave-
form or gated region and is measured in volt--seconds. The area mea-
sured above the ground is positive, while the area below ground is
negative.
H BURst
The burst width measures the duration of a burst. The measurement is
made over the entire waveform or gated region.