EasyManuals Logo

Tektronix TDS5000B Series Online Programmer Guide

Tektronix TDS5000B Series
917 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #610 background imageLoading...
Page #610 background image
TDS5000B Online Programmer Guide
-- 5 9 0 --
H CARea
The cycle area measures the voltage over time. In other words, it mea-
sures, in volt--seconds, the area over the first cycle in the waveform or
the first cycle in the gated region. The area measured above the com-
mon reference point is positive, while the area below the common
reference point is negative.
H CMEan
This measures the arithmetic mean over the first cycle in the wave-
form or the first cycle in the gated region.
H CRMs
This measures the true Root Mean Square voltage over the first cycle
in the waveform or the first cycle in the gated region.
H DELay
This measures the time between the middle reference (default = 50%)
amplitude point of the source waveform and the destination wave-
form.
H DISTDUty
The duty cycle distortion measures the time between the falling edge
and the rising edge of the eye pattern at the mid reference level.
It is the peak--to--peak time variation of the first eye crossing mea-
sured at the mid--reference as a percent of the eye period.
H EXTINCTDB
This (optical waveform (eye diagram) measurement) measures its
extinction ratio. Extinction Ratio (dB) measures the ratio of the aver-
age power levels for the logic High to the logic Low of an optical wa-
veform and expresses the result in dB.
This measurement only works for fast acquisition signals or a refer-
ence waveform saved in fast acquisition mode.
Extinction dB = 10 X (log 10 (High / Low)
H EXTINCTPCT
This (optical measurement) measures the extinction ratio of the se-
lected optical waveform. Extinction Ratio (%) measures the ratio of
the average power levels for the logic Low (off) to the logic (High)
(on) of an optical waveform and expresses the result in percent.
This measurement only works for fast acquisition signals or a refer-
ence waveform saved in fast acquisition mode.
Extinction % = 100.0 x (Low / High)
H EXTINCTRATIO
This (optical measurement) measures the extinction ratio of the se-
lected optical waveform. Extinction Ratio measures the ratio of the
average power levels for the logic High to the logic Low of an optical
waveform and expresses the result without units.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals