TRIGger:A:LOGIc:PATtern:WHEn:MORELimit
Description
This command sets or queries the minimum time that the selected pat-
tern may be true and still generate an A logic pattern trigger. This com-
mand is equivalent to selecting A Event (Main) Trigger Setup from the
Trig menu, selecting Pattern as the Trigger Type, selecting More Than
for the Pattern in the Trigger When settings, and entering a minimum
value for Time.
Group
Trigger
Related Commands
TRIGger:A:LOGIc:PATtern:WHEn:LESSLimit
Syntax 1
TRIGger:A:LOGIc:PATtern:WHEn:MORELimit <NR3>
Syntax 2
TRIGger:A:LOGIc:PATtern:WHEn:MORELimit?
Argument
H <NR3>
This specifies the amount of time to hold the pattern true.
Example 1
TRIGger:A:LOGIc:PATtern:WHEn:MORELimit?
This query might return
:TRIGGER:A:LOGIC:PATTERN:WHEN:MORELIMIT
5.0000E-09
indicating that the selected pattern must hold true for at least 5 ns to
generate an A logic pattern trigger.
Example 2
TRIGger:A:LOGIc:PATtern:WHEn:MORELimit
10.0E+00
This command sets the minimum time that the selected pattern may
hold true (and generate an A logic pattern trigger) to 10 s.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals