TDS5000B Online Programmer Guide
-- 7 3 8 --
TRIGger:A:PULse:TRANsition:WHEn
Description
This command sets or queries whether to check for a transitioning sig-
nal that is faster or slower than the specified delta time. This is equiva-
lent to selecting Transition Setup from the Trig menu and choosing the
Trigger When Transition Time setting.
Group
Trigger
Related Commands
TRIGger:A:PULse:TRANsition:DELTATime, TRIG-
ger:A:PULse:TRANsition:POLarity, TRIGger:A:PULse:TRANsi-
tion:THReshold?
Syntax 1
TRIGger:A:PULse:TRANsition:WHEn {FASTERt-
han|SLOWERthan}
Syntax 2
TRIGger:A:PULse:TRANsition:WHEn?
Arguments
H FASTERthan
This sets the trigger to occur when the transitioning signal is faster
than the set volts/second rate.
H SLOWERthan
This sets the trigger to occur when the transitioning signal is slower
than the set volts/second rate.
Example 1
TRIGger:A:PULse:TRANsition:WHEn?
This query might return
:TRIGGER:A:PULSE:TRANSITION:WHEN FASTERTHAN
indicating that the transition triggers when the transitioning signal is
faster than the set volts/second rate.
Example 2
TRIGger:A:PULse:TRANsition:WHEn SLOWERthan