-- 7 3 7 --
TRIGger:A:PULse:TRANsition:THReshold?
Description
This query--only command returns the upper and lower threshold limits
for the transition time trigger. This command is equivalent to selecting
Transition Setup from the Trig menu and viewing the Upper Level and
Lower Level voltage settings.
Group
Trigger
Related Commands
TRIGger:A:PULse:TRANsition:DELTATime,
TRIGger:A:PULse:TRANsition:POLarity
Syntax
TRIGger:A:PULse:TRANsition:THReshold?
Example
TRIGger:A:PULse:TRANsition:THReshold?
This query might return
:TRIGGER:A:PULSE:TRANSITION:THRESHOLD:HIGH
1.2000;LOW 800.0000E-3
indicating the upper and lower threshold limits for the transition time
trigger.