TDS5000B Online Programmer Guide
-- 7 1 5 --
TRIGger:A:PULse:RUNT:LOGIc:INPUT:CH<x>
Description
This command sets or queries the A runt logic input for the channel
specified by <x>, which can be 1, 2, 3, or 4. This is equivalent to set-
ting the runt logic inputs from the Trigger When section in the Runt
Trigger menu. While all channels can be set or queried, only channels 3
and 4 can be used if the runt source is channel 1 or 2. Similarly, only
channels 1 and 2 can be used if the runt source is channel 3 or 4.
Note: This command is not available in two--channel instruments.
Group
Trigger
Syntax 1
TRIgger:A:PULse:RUNT:LOGIc:INPUT:CH<x>
{HIGH|LOW|X}
Syntax 2
TRIgger:A:PULse:RUNT:LOGIc:INPUT:CH<x>?
Arguments
H HIGH
This argument specifies logic high.
H LOW
This argument specifies logic low.
H X
This argument specifies a don’t care state.
Example 1
TRIgger:A:PULse:RUNT:LOGIc:INPUT:CH2?
This query might return
:TRIGGER:A:PULSE:RUNT:LOGIC:INPUT CH2 LOW
indicating that the runt logic trigger input is set to logic low for chan-
nel 2.
Example 2
TRIgger:A:PULse:RUNT:LOGIc:INPUT:CH3 HIGH
This command sets the runt logic trigger input to logic high for chan-
nel 3.