TDS5000B Online Programmer Guide
-- 2 7 7 --
EMail:TIMEout
Description
This command sets or queries the global timeout in seconds. The de-
fault is 30 seconds. You use this timeout for socket connections and
may need to change it from the default on some networks.
Group
Email
Syntax 1
EMail:TIMEout <NR1>
Syntax 2
EMail:TIMEout?
Argument
H <NR1>
This argument is the global timeout in seconds. The value for NR1
can be 0 through 500.
Example 1
EMail:TIMEout 60
This command specifies that 60 seconds will be used for network con-
nection timeouts.
Example 2
EMail:TIMEout?
This query might return
:EMAIL:TIMEOUT 30
This indicates that the default of 30 seconds is set for network connec-
tion timeouts.