TDS5000B Online Programmer Guide
-- 7 5 1 --
TRIGger:A:PULse:WINdow:THReshold:HIGH
Description
This command sets or queries the upper limit for the pulse window trig-
ger. This command is equivalent to selecting Window Setup from the
Trig menu and setting the window trigger Upper Level voltage.
Group
Trigger
Syntax 1
TRIGger:A:PULse:WINdow:THReshold:HIGH <NR3>
Syntax 2
TRIGger:A:PULse:WINdow:THReshold:HIGH?
Argument
H <NR3>
This specifies the threshold value in volts.
Example 1
TRIGger:A:PULse:WINdow:THReshold:HIGH?
This query might return
:TRIGGER:A:PULSE:WINDOW:THRESHOLD:HIGH
1.1000E+00
indicating that the upper limit of the window trigger is set to 1.1 V.
Example 2
TRIGger:A:PULse:WINdow:THReshold:HIGH 2.0
This command sets the upper limit of the pulse window trigger to 2 V.