-- 6 7 3 --
TRIGger:A:HOLDoff:ACTUal?
Description
This query--only command returns the holdoff time actually used (ex-
pressed in seconds) by the A trigger. This command is equivalent to
selecting Holdoff from the Trig menu and then viewing the current Trig
Holdoff value.
Group
Trigger
Related Commands
TRIGger:A:HOLDoff?, TRIGger:A:HOLDoff:BY,
TRIGger:A:HOLDoff:TIMe
Syntax
TRIGger:A:HOLDoff:ACTUal?
Example
TRIGger:A:HOLDoff:ACTUal?
This query might return
:TRIGGER:A:HOLDOFF:ACTUAL 4.0000E-06
showing that the holdoff time is set to 4 µs.