TDS5000B Online Programmer Guide
-- 3 6 9 --
HORizontal:MAIn:UNIts
Description
This command sets or returns the units for the horizontal time base. It is
equivalent to setting the HORizontal:MAIn:UNIts:STRing
Group
Horizontal
Related Commands
HORizontal:MAIn:UNIts:STRing
Syntax 1
HORizontal:MAIn:UNIts <STRing>
Syntax 2
HORizontal:MAIn:UNIts?
Arguments
H <STRing>
This is the time base units string.
Example 1
HORizontal:MAIn:UNIts ”lum”
This command sets the time base multiplier to 5.5, the units to lumens
and the time base units offset to 2.9.
Example 2
HORizontal:MAIn:UNIts?
This query might return:
:HORIZONTAL:MAIN:UNITS STRING ”lum”.