TDS5000B Online Programmer Guide
-- 6 9 1 --
TRIGger:A:LOGIc:SETHold:CLOCk:EDGE
Description
This command sets or queries the clock edge polarity for setup and hold
triggering. This is equivalent to selecting Setup/Hold Setup from the
Trig menu and then choosing the desired Clock Edge.
Group
Trigger
Related Commands
TRIGger:A:LOGIc:SETHold:CLOCk:SOUrce, TRIGger:A:LOGIc:SE-
THold:CLOCk:THReshold
Syntax 1
TRIGger:A:LOGIc:SETHold:CLOCk:EDGE {FALL|RISe}
Syntax 2
TRIGger:A:LOGIc:SETHold:CLOCk:EDGE?
Arguments
H FALL
This specifies polarity as the clock falling edge.
H RISe
This specifies polarity as the clock rising edge.
Example 1
TRIGger:A:LOGIc:SETHold:CLOCk:EDGE?
This query might return
:TRIGGER:A:LOGIC:SETHOLD:CLOCK:EDGE RISE
indicating that polarity is specified as the clock rising edge.
Example 2
TRIGger:A:LOGIc:SETHold:CLOCk:EDGE RISE
This command specifies the polarity as the clock rising edge.