TDS5000B Online Programmer Guide
-- 6 9 7 --
TRIGger:A:LOGIc:SETHold:DATa?
Description
This query--only command returns the voltage threshold and data
source for the setup and hold trigger. This command is equivalent to
selecting Setup/Hold Setup from the Trig menu and then viewing the
current data setups.
Group
Trigger
Related Commands
TRIGger:A:LOGIc:SETHold:CLOCk?
Syntax
TRIGger:A:LOGIc:SETHold:DATa?
Example
TRIGger:A:LOGIc:SETHold:DATa?
This query might return
:TRIGGER:A:LOGIC:SETHOLD:DATA:THRESHOLD
1.4000;SOURCE CH1
indicating the current trigger data settings.