EasyManuals Logo

Tektronix TDS5000B Series Online Programmer Guide

Tektronix TDS5000B Series
917 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
TDS5000B Online Programmer Guide
-- 3 9 --
Command Description
MEASUrement:GATing Sets or returns the measurement
gating
MEASUrement:IMMed? Returns all immediate measure-
ment setup parameters
MEASUrement:IMMed:DElay? Returns information about the
immediate delay measurement
MEASUrement:IMMed:DELay:DIREction Sets or returns the search direc-
tion to use for immediate delay
measurements
MEASUrement:IMMed:DElay:EDGE[1] Sets or returns the slope of the
edge used for immediate delay
”from” waveform measurements
MEASUrement:IMMed:DElay:EDGE2 Sets or returns the slope of the
edge used for immediate delay
”to” waveform measurements
MEASUrement:IMMed:NOISe Sets or returns the location of
the noise measurement on the
eye waveform
MEASUrement:IMMed:REFLevel:
ABSolute:HIGH
Sets or returns the high refer-
ence level
MEASUrement:IMMed:REFLevel:
ABSolute:LOW
Sets or returns the low reference
level
MEASUrement:IMMed:REFLevel:
ABSolute:MID[1]
Sets or returns the middle refer-
ence level
MEASUrement:IMMed:REFLevel:
ABSolute:MID2
Sets or returns the middle refer-
ence level for delay measure-
ments
MEASUrement:IMMed:REFLevel:
METhod
Sets or returns the method used
to calculate measurements
MEASUrement:IMMed:REFLevel:
PERCent:HIGH
Sets or returns the top level for
rise time (90% level)
MEASUrement:IMMed:REFLevel:
PERCent:LOW
Sets or returns the low level for
rise time (10% level)
MEASUrement:IMMed:REFLevel:
PERCent:MID[1]
Sets or returns the mid level for
measurements
MEASUrement:IMMed:REFLevel:
PERCent:MID2
Sets or returns the mid level for
delay measurements
MEASUrement:IMMed:REFLevel? Returns the reference levels
MEASUrement:IMMed:SOURCE[1] Sets or returns the ”from” source
for all single channel immediate
measurements
MEASUrement:IMMed:SOURCE2 Sets or returns the source to
measure ”to” for phase or delay
immediate measurements
MEASurement:IMMed:SOUrce<x>:
SIGType
Sets or returns the type of input
signal used for the specified
measurement source
MEASUrement:IMMed:TYPe Sets or returns the type of the
immediate measurement
MEASUrement:IMMed:UNIts? Returns the units of the immedi-
ate measurement
MEASUrement:IMMed:VALue? Returns the value of the immedi-
ate measurement

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals