TDS5000B Online Programmer Guide
-- 3 6 --
MASK:TESt:STATUS?
Returns the pass/fail test status
MASK:TESt:STOP:FAILure
Sets or returns the stop status on
pass/fail test failure mode
MASK:TESt:THReshold
Sets or returns the number of failed
tested waveforms needed in each
pass/fail test to cause the pass/fail sta-
tus to change from PASSING to FAIL-
ING
MASK:TESt:WAVEform
Sets or returns the number of wave-
forms to test during pass/fail testing
MASK:USER:AMPlitude
Sets or returns the current mask’s
nominal pulse amplitude in volts
MASK:USER:BITRate
Sets or returns the user mask’s bit rate
MASK:USER:HSCAle
Sets or returns the nominal timing res-
olution used to draw the mask, in time/
division
MASK:USER:HTRIGPOS
Sets or returns the nominal tripper
position.(pulse leading edge) used to
draw the mask as a fraction of the dis-
play width
MASK:USER:LABel
Sets or returns the label assigned to a
user mask
MASK:USER:PATTERN-
BITS
Sets or returns the number of bits used
for serial trigger for the User mask
standard
MASK:USER:PRESAMP-
BITS
Sets or returns the number of bits be-
fore the (isolated one) pulse leading
edge in the serial trigger pass/fail test-
ing
MASK:USER:RECOrd-
length
Sets or returns the nominal record
length for pulse mask testing
MASK:USER:SEG<m> DE-
LEte
Deletes the specified mask segment
from the User mask
MASK:USER:SEG<m>:NR
_Pt?
Returns the number of points that
make up the specified User mask seg-
ment
MASK:USER:SEG<m>:POI
NTS
Sets or returns the X--Y user coordi-
nates of all points in the specified User
mask segment
MASK:USER:TRIGTO-
SAMP
Sets or returns the time, in seconds,
from the (leading edge) trigger position
to the pulse bit sampling position
MASK:USER:VOFFSet
Sets or returns the nominal vertical off-
set, in volts, used to vertically offset the
input channels
MASK:USER:VPOS
Sets or returns the nominal vertical
position, in divisions, used to vertically
position the input channels
MASK:USER:VSCAle
Sets or returns the nominal vertical
scale, in volts per division, used to ver-
tically scale the input channels
MASK:USER:WIDth
Sets or returns the nominal bit width in
seconds
RECAll:MASK
Recalls a stored mask as the User
mask.
SAVe:MASK
Saves the User mask to a mass stor-
age file

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals