Switching Commands
137
ProSAFE M7100 Managed Switches
no lldp receive
Use this command to return the reception of LLDPDUs to the default value.
lldp timers
Use this command to set the timing parameters for local data transmission on ports enabled for
LLDP. The <interval-seconds> determines the number of seconds to wait between
transmitting local data LLDPDUs. The range is 1-32768 seconds. The <hold-value> is the
multiplier on the transmit interval that sets the TTL in local data LLDPDUs. The multiplier range is
2-10. The <reinit-seconds> is the delay before re-initialization, and the range is 1-0
seconds.
no lldp timers
Use this command to return any or all timing parameters for local data transmission on ports
enabled f
or LLDP t
o the default values.
lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the 802.1AB basic
management set are transmitted in the LLDPDUs. Use <sys-name> to transmit the system
name TLV. To configure the system name, see snmp-server on page 541. Use <sys-desc> to
tr
ansmit the system description TLV. Use sys-cap to tr
ansmit the system capabilities TLV. Use
<port-desc> to transmit the port description TLV. To configure the port description, see
description on page 23
Format no lldp receive
Mode Interface Config
Default interval—30 seconds
hold—4
r
einit—2 seconds
Format lldp timers [interval <interval-seconds>] [hold <hold-value>]
[reinit <reinit-seconds>]
Mode Global Config
Format no lldp timers [interval] [hold] [reinit]
Mode Global Config
Default All optional TLVs are included
Format lldp transmit-tlv [sys-desc] [sys-name] [sys-cap] [port-desc]
Mode Interface Config