Switching Commands
71
ProSAFE M7100 Managed Switches
disabled on that interface. GARP functionality is subsequently re-enabled if routing is disabled
and port-channel (LAG) membership is removed from an interface that has GARP enabled.
no set gmrp interfacemode
This command disables GARP Multicast Registration Protocol on a single interface or all
inter
faces. If an interface which has GARP enabled is enabled for routing or is enlisted as a
member of a port-channel (LAG), GARP functionality is disabled. GARP functionality is
subsequently re-enabled if routing is disabled and port-channel (LAG) membership is removed
from an interface that has GARP enabled.
show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or all
interfaces.
Default disabled
Format set gmrp interfacemode
Mode • Interface Config
• Global Config
F
ormat no set gmrp interfacemode
Mode • Interface Config
• Global Config
F
ormat show gmrp configuration {<slot/port> | all}
Mode • Privileged EXEC
• User EXEC
Term Definition
Interface The slot/port of the interface that this row in the table describes.
Join Timer The interval between the transmission of GARP PDUs registering (or re-registering)
membership for an attribut
e. Current attributes are a VLAN or multicast group. There is an
instance of this timer on a per-Port, per-GARP participant basis. Permissible values are
10–100 centiseconds (0.1 to 1.0 seconds). The factory default is 20 centiseconds (0.2
seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer The period of time to wait after receiving an unregister request for an attribute before
dele
ting the attribut
e. Current attributes are a VLAN or multicast group. This may be
considered a buffer time for another station to assert registration for the same attribute in
order to maintain uninterrupted service. There is an instance of this timer on a per-Port,
per-GARP participant basis. Permissible values are 20–600 centiseconds (0.2 to 6.0
seconds). The factory default is 60 centiseconds (0.6 seconds).

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals