Switching Commands
67
ProSAFE M7100 Managed Switches
This can be considered a buffer time for another station to assert registration for the same
attribute in order to maintain uninterrupted service. The leave time is 20–600 (centiseconds).
The value 60 centiseconds is 0.6 seconds.
no set garp timer leave
This command sets the GVRP leave time on all ports or a single port to the default and only has an
eff
ect when GVRP is enabled.
set garp timer leaveall
This command sets how frequently Leave All PDUs are generated. A Leave All PDU indicates that
all registrations will be unregistered. Participants would need to rejoin in order to maintain
registration. The value applies per port and per GARP participation. The time may range from 200
to 6000 (centiseconds). The value 1000 centiseconds is 10 seconds. You can use this command
on all ports (Global Config mode) or a single port (Interface Config mode), and it only has an
effect only when GVRP is enabled.
no set garp timer leaveall
This command sets how frequently Leave All PDUs are generated the default and only has an
ef
f
ect when GVRP is enabled.
Default 60
Format set garp timer leave <20-600>
Mode Interface Config
Global Config
F
ormat no set garp timer leave
Mode Interface Config
Global Config
Def
ault 1000
Format set garp timer leaveall <200-6000>
Mode Interface Config
Global Config
F
ormat no set garp timer leaveall
Mode Interface Config
Global Config