Switching Commands
23
ProSAFE M7100 Managed Switches
no auto-negotiate
This command disables automatic negotiation on a port.
Note: Automatic sensing is disabled when automatic negotiation is disabled.
auto-negotiate all
This command enables automatic negotiation on all ports.
no auto-negotiate all
This command disables automatic negotiation on all ports.
description
Use this command to create an alpha-numeric description of the port.
mtu
Use the mtu command to set the maximum transmission unit (MTU) size, in bytes, for frames
that ingress or egress the interface. You can use the mtu command to configure jumbo frame
support for physical and port-channel (LAG) interfaces. For the standard 7000 series
implementation, the MTU size is a valid integer between 1522–9216 for tagged packets and a
valid integer between 1518–9216 for untagged packets.
Note: To receive and process packets, the Ethernet MTU must include any
extra bytes that Layer-2 headers might require. To configure the IP
MTU size, which is the maximum size of the IP packet (IP Header + IP
payload), see ip mtu on page 183.
Default enabled
Format auto-negotiate all
Mode Global Config
Format no auto-negotiate all
Mode Global Config
Format description <description>
Mode Interface Config

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals