Utility Commands
397
ProSAFE M7100 Managed Switches
no logging email logtime
This command resets the non-urgent log time to the default value.
logging traps
This command sets the severity at which SNMP traps are logged and sent in an email. You can
specify the <severitylevel> parameter either as an integer from 0 to 7 or symbolically
through one of the following keywords: emergency (0), alert (1), critical (2), error
(3), warning (4), notice (5), info (6), or debug (7).
no logging traps
This command resets the SNMP trap logging severity level to the default value.
logging email test message-type
This command sends an email to the SMTP server to test the email alerting function.
show logging email config
This command displays information about the email alert configuration.
Format no logging email logtime
Mode Global Config
Default Info (6) messages and higher are logged.
Format logging traps <severitylevel>
Mode Global Config
Format no logging traps
Mode Global Config
Format logging email test message-type {urgent | non-urgent | both}
message-body <message-body>
Mode Global Config
Format show logging email config
Mode Privileged EXEC
Term Definition
Email Alert Logging The administrative status of the feature: enabled or disabled
Email Alert From Address The email address of the sender (the switch).